DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630)

DIN 268 tangential keys and keyways for alternating shock loads — pairs of round-ended keys set tangentially on large shafts from 100 to 630 mm, tabulated with key width b and keyway depths per shaft size; the standard is withdrawn (09/1974) and carried as the legacy reference.

Last updated: 2026-11

Request a Quote

DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630) in an industrial setting
Illustrative image redrawn from real DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630) product references — not a photograph of stocked items.

Specifications

Tangential keys are the heavy-drive answer to a problem a parallel key cannot survive: instead of one key sheared across the shaft centre, a DIN 268 set is two round-ended keys laid tangentially near the shaft surface, so the torque path runs through the strong outer fibres of the shaft and the pair takes load in compression rather than in shear. That construction is why this key form shows up where loads reverse violently — rolling-mill drives, heavy gear couplings, presses — and why the tabulated shaft ladder starts where ordinary keys stop: 100 mm diameter up to 630 mm. The collected grid carries, per shaft size, the key width b (30 at d 100 up to 180 at d 630), the c value and the keyway depth d (10.3 at d 100 up to 60.5 at d 630 — the keyway column runs just ahead of c, a consistent +0.3 to +0.5 allowance over the key value). One status note comes before any sizing: the source page dates this standard 09/1974 and marks it WITHDRAWN, with no successor named — so the grid is the collected reference for the legacy designation, and a live drawing that still calls DIN 268 should be confirmed against the current governing document at quotation. The final tabulated row (b 189) prints no shaft-diameter cell in the source and is carried truncated rather than inferred. Key material, finish and length are not tabulated — per RFQ.

Standard / scope DIN 268 tangential keys and tangential keyways for alternating shock loads ("stoßartige Wechselbeanspruchung") — source title as printed, trilingual (EN/IT/DE); publication date 09/1974, marked WITHDRAWN on the source page, no successor named
Shaft range (d) 100 to 630 mm, 33 tabulated rows: 100/110/120/125/130/140/150/160/170/180/190/200, then 220–500 in the standard heavy series, 530/560/600/630 — the final row (b 189) prints no shaft cell (truncated in the source, see the table flag)
Key width (b) 30 mm at d 100 rising to 180 mm at d 630 (b 189 on the truncated final row) — b is the key width the paired keys are cut to
Keyway depth (d keyway) 10.3 at d 100 to 60.5 at d 630, consistently 0.3–0.5 above the c value on every row — the keyway allowance the hub and shaft bores are cut to
Not tabulated No material, finish, key length or tolerance line is printed on the source page; key length is a per-order dimension — per RFQ
DIN 268 tangential keys and keyways for alternating shock loads — shaft 100–630 mm (standard withdrawn 09/1974)All dimensions in millimetres (source caption prints "Dimensions in mm"). Column labels b / c key / d keyway / d shaft diameter are carried verbatim from the source grid. A tangential key set is a pair of round-ended keys laid tangentially on the shaft circumference; the shaft diameter d selects the row. Materials, finishes and key lengths are not tabulated — per RFQ.
Key Width (b)c (key)d (keyway)Shaft Diameter (d)
301010.3100
331111.4110
361212.4120
37.512.512.9125
391313.4130
421414.4140
451515.4150
481616.4160
511717.4170
541818.4180
571919.4190
602020.4200
662222.4220
722424.4250
752525.4260
782626.4280
842828.4300
903030.4320
963232.4340
1023434.4360
1083636.4380
1143838.4400
1204040.4420
1264242.4440
1324444.4450
1354545.4460
1384646.4480
1444848.4500
1505050.5530
1595353.5560
1685656.5600
1806060.5630
1896363.5—
  • Row 33 (189): The final row (b 189, c 63, keyway 63.5) prints no shaft-diameter cell in the source grid — the tabulated shaft ladder ends at 630 on the b 180 row. The 189 row shaft size is not established from this capture; the truncated row is carried verbatim, not inferred.
  • Row 1 (30): The source page dates this standard 09/1974 and marks it WITHDRAWN — the grid is carried as the collected reference for the legacy designation; no successor standard is named on the source page. Confirm the current governing document at RFQ.

Materials

  • The source page prints no makings line, so this page makes no material claim beyond the dimension grid. Tangential keys are supplied in steel; for heavy alternating drives the certificate and material grade are engineering decisions that belong on the RFQ, not assumptions from a dimension table. State the shaft diameter (which selects the row), key width b, the mating hub and shaft keyway depths, material and certificate requirement, and quantity per size — commercial terms are confirmed at quotation.

Ordering & documentation

Documents

Shipments of DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630) are backed by Mill Test Certificate (MTC), Dimensional Report, Salt Spray Test Report on request, with full batch traceability from raw material to finished product. Quality management for DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630) orders follows the owner-confirmed compliance list: ISO 9001:2015, RoHS, REACH. Exact document sets are confirmed on the order.

Quotation

  • The product family (DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630)), product standard/designation and drawing or part number.
  • The dimensions that apply to this part — such as size, pitch, length, thickness, fit, grip or groove geometry.
  • Material/grade, heat-treatment condition and surface finish, together with the service environment.
  • Quantity per size, delivery destination and required test or traceability documents.

Sample & supply

Minimum order quantities and lead times for din 268 tangential keys for alternating shock loads (d 100 – 630) are confirmed at quotation — send pin type, diameter, length and material on the RFQ and the quote will carry a firm schedule; sample availability is confirmed with the quotation.

Storage & shipping

DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630) are packed for export and shipped factory-direct to buyers in Europe, Asia, the Americas and the Middle East. Store din 268 tangential keys for alternating shock loads (d 100 – 630) dry and protected until installation, and keep coated parts in their packaging until use; specific packing and preservation requirements can be stated on the order and confirmed at quotation.

Frequently asked questions

When does a tangential key (DIN 268/DIN 271) replace a parallel or taper key?

By torque magnitude and reversals, not by preference. A conventional key sits across the shaft centre and transmits torque in shear over its cross-section — adequate for ordinary drives, but at large shaft diameters the shear area does not keep up with the torque. A tangential pair moves the working faces out to the shaft surface where the lever arm is largest and loads the keys in compression, which is why both standards tabulate from d 60–100 upward and why the form lives on heavy drives. DIN 268 is specifically the alternating-shock variant — reversing, impact-laden torque — while DIN 271 covers the same construction under constant load, and its ladder runs to smaller shafts (60 vs 100 mm). If your hub could be served by a DIN 6885 parallel key in the sizes it tabulates (up to 100×56 sections), start there; the tangent-key pair earns its complicated keyway geometry only where the drive torque and reversals demand it.

The standard is marked withdrawn — can I still order DIN 268 keys?

You can order the part; treat the paper carefully. The source page dates DIN 268 09/1974 and marks it withdrawn without naming a successor, and this page carries the collected grid as the reference for the legacy designation — it does not substitute a current standard's numbers. In practice withdrawn DIN key standards keep their callouts on legacy drawings and heavy-plant spares lists, and manufacturers cut to the drawing. The safe pattern: order by the drawing designation (DIN 268, shaft diameter d, key width b) and ask the supplier to confirm the governing document the keys are certified against at quotation — if your plant standard has adopted a successor or an ISO equivalent, say so on the RFQ so paperwork matches. What you should not do is mix the DIN 268 (alternating) and DIN 271 (constant) ladders freely: the b and keyway values differ at the same shaft size (d 100 is b 30 under DIN 268 but b 28.6 under DIN 271), so a mixed callout produces a key that does not seat.

How do I read the c and d-keyway columns against each other?

They travel together on a fixed allowance. On every DIN 268 row the keyway depth d prints 0.3–0.5 above the c value: 10/10.3 at d 100, 14/14.4 at d 200, 60/60.5 at d 630. c is the key-side reference value; d is the keyway depth actually cut into shaft and hub. So you do not pick them independently — select the row by shaft diameter, quote b for the keys, and cut the keyways to the d column of the same row. If a mating part arrives with keyways cut to the other standard's row (the DIN 271 depths differ at the same shaft size), the pair will not seat; check both mating bores against one row before machining.

What should an RFQ for DIN 268 tangential keys state?

Shaft diameter (it selects the table row), key width b, the standard designation with the alternating-load variant made explicit (DIN 268, not DIN 271), material and any certificate requirement, quantity per size, and the mating hub drawing reference if the supplier is to confirm keyway fit. Confirm at quotation: the current governing document for the withdrawn designation (see the status FAQ), the truncated final ladder row (b 189 — its shaft size is not established from the collected grid), and anything outside the tabulated shaft range 100–630.

Request a Quote

Get factory-direct pricing from the manufacturer.

What to include in your DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630) inquiry

  • ✓ Identify the pin type and its standard (for example parallel dowel or slotted spring pin).
  • ✓ Give nominal diameter, length and required fit/tolerance; include the mating-hole size and whether it is drilled or reamed.
  • ✓ State material, heat-treatment condition and corrosion finish, plus any specified shear or retention duty.
  • ✓ Give quantity per size, destination and inspection/certificate requirements.
  • ✓ Factory-direct pricing for your DIN 268 Tangential Keys for Alternating Shock Loads (d 100 – 630)
  • ✓ Standard and custom specifications
  • ✓ Factory-direct export to buyers in Europe, Asia, the Americas and the Middle East
  • ✓ Full fastener family support

We use your details only to answer this inquiry — see our Privacy notice for everything the form collects.